Frog-D Generator Displays
Single Phase
Three Phase
Features
- Displays Frequency, Voltage, and Current
- Ideal for Hydraulic, Diesel Powered, and PTO Generators
- Rated for 50/60 Hz Generators from 6 to 45 kW
- Highly Visible Ultra-Bright LEDs
- MODE Button Displays Total Generator Hrs. and Hydraulic Oil Temp.
- Built-in Warning for Current Overloads, Voltage Fluctuations, and High Hydraulic Oil Temperature
- Optional Hydraulic Oil Temperature Sensor and Audible Alarm Buzzer
Features
- Displays Frequency, Line Voltage (Phase to Neutral or Phase to Phase), and Current on Each Line
- Monitor Each Line Individually or Scan All Lines Continuously
- Rated for 50/60 Hz Generators from 10 to 135 kW
- Generator Hourmeter
- Built-in Warning for Current Overloads, Voltage Fluctuations, and High Hydraulic Oil Temperature
- Optional Hydraulic Oil Temperature Sensor and Audible Alarm
The three phase signal interface module is mounted close to the current sensors and voltage transformers so that cable runs are short.
Current and voltage information is passed to the display module over a two-wire datalink.
Ordering Information
STANDARD KIT includes:
- Single Phase – display module, 2 current sensors, AC voltage transformer, and cables.
- Three Phase – display module, signal interface module, 3 current sensors, 3 AC voltage transformers, & cables.
Kit Numbers | Description |
---|---|
FDA100-XXX | Frog-D, Single Phase |
FDA700-XXX | Frog-D, Three Phase, Delta Windings |
FDA710-XXX | Frog-D, Three Phase, Star Windings |
XXX = Generator Power Rating in Kilowatts.
- Single Phase rated 6 to 45 kW
- Three Phase rated 10 to 135 kW
Dimensions:
- 4.25″ (H) x 4.25″(W)
108 mm (H) x 108 mm (W) - Interface Module
3.8″ x 5.9″ x 1.9″
97 mm x 150 mm x 48 mm
Options:
- Audible Alarm Buzzer
- Hydraulic Oil Temperature Sensor
Documents & Downloads
File | File Type | Link |
---|---|---|
FDA100-045 Generator display, Frog-D, single phase, 60Hz 45kW |
rtf | |
FDA100-040 Generator display, Frog-D, single phase, 60Hz 40kW |
rtf | |
FDA100-035 Generator display, Frog-D, single phase, 60Hz 35kW |
rtf | |
FDA100-030 Generator display, Frog-D, single phase, 60Hz 30kW |
rtf | |
FDA100-025 Generator display, Frog-D, single phase, 60Hz 25kW |
rtf | |
FDA100-020 Generator display, Frog-D, single phase, 60Hz 20kW |
rtf | |
FDA100-015 Generator display, Frog-D, single phase, 60Hz 15kW |
rtf | |
FDA100-012 Generator display, Frog-D, single phase, 60Hz 12kW |
rtf | |
FDA100-010 Generator display, Frog-D, single phase, 60Hz 10kW |
rtf | |
FDA100-009 Generator display, Frog-D, single phase, 60Hz 9kW |
rtf | |
FDA100-008 Generator display, Frog-D, single phase, 60Hz 8kW |
rtf | |
FDA100-007 Generator display, Frog-D, single phase, 60Hz 7kW |
rtf | |
FDA100-006 Generator display, Frog-D, single phase, 60Hz 6kW |
rtf | |
FDA710-125 Generator display, Frog-D, 3 phase, Star, 60Hz 125kW |
rtf | |
FDA710-115 Generator display, Frog-D, 3 phase, Star, 60Hz 115kW |
rtf | |
FDA710-120 Generator display, Frog-D, 3 phase, Star, 60Hz 120kW |
rtf | |
FDA710-130 Generator display, Frog-D, 3 phase, Star, 60Hz 130kW |
rtf | |
FDA710-135 Generator display, Frog-D, 3 phase, Star, 60Hz 135kW |
rtf | |
FDA710-110 Generator display, Frog-D, 3 phase, Star, 60Hz 110kW |
rtf | |
FDA710-105 Generator display, Frog-D, 3 phase, Star, 60Hz 105kW |
rtf | |
FDA710-100 Generator display, Frog-D, 3 phase, Star, 60Hz 100kW |
rtf | |
FDA710-095 Generator display, Frog-D, 3 phase, Star, 60Hz 95kW |
rtf | |
FDA710-090 Generator display, Frog-D, 3 phase, Star, 60Hz 90kW |
rtf | |
FDA710-085 Generator display, Frog-D, 3 phase, Star, 60Hz 85kW |
rtf | |
FDA710-070 Generator display, Frog-D, 3 phase, Star, 60Hz 70kW |
rtf | |
FDA710-075 Generator display, Frog-D, 3 phase, Star, 60Hz 75kW |
rtf | |
FDA710-080 Generator display, Frog-D, 3 phase, Star, 60Hz 80kW |
rtf | |
FDA710-065 Generator display, Frog-D, 3 phase, Star, 60Hz 65kW |
rtf | |
FDA710-060 Generator display, Frog-D, 3 phase, Star, 60Hz 60kW |
rtf | |
FDA710-055 Generator display, Frog-D, 3 phase, Star, 60Hz 55kW |
rtf | |
FDA710-050 Generator display, Frog-D, 3 phase, Star, 60Hz 50kW |
rtf | |
FDA710-045 Generator display, Frog-D, 3 phase, Star, 60Hz 45kW |
rtf | |
FDA710-040 Generator display, Frog-D, 3 phase, Star, 60Hz 40kW |
rtf | |
FDA710-035 Generator display, Frog-D, 3 phase, Star, 60Hz 35kW |
rtf | |
FDA710-030 Generator display, Frog-D, 3 phase, Star, 60Hz 30kW |
rtf | |
FDA710-025 Generator display, Frog-D, 3 phase, Star, 60Hz 25kW |
rtf | |
FDA710-020 Generator display, Frog-D, 3 phase, Star, 60Hz 20kW |
rtf | |
FDA710-015 Generator display, Frog-D, 3 phase, Star, 60Hz 15kW |
rtf | |
FDA710-010 Generator display, Frog-D, 3 phase, Star, 60Hz 10kW |
rtf | |
FDA700-135 Generator display, Frog-D, 3 phase, Delta, 60Hz 135kW |
rtf | |
FDA700-130 Generator display, Frog-D, 3 phase, Delta, 60Hz 130kW |
rtf | |
FDA700-125 Generator display, Frog-D, 3 phase, Delta, 60Hz 125kW |
rtf | |
FDA700-120 Generator display, Frog-D, 3 phase, Delta, 60Hz 120kW |
rtf | |
FDA700-115 Generator display, Frog-D, 3 phase, Delta, 60Hz 115kW |
rtf | |
FDA700-110 Generator display, Frog-D, 3 phase, Delta, 60Hz 110kW |
rtf | |
FDA700-105 Generator display, Frog-D, 3 phase, Delta, 60Hz 105kW |
rtf | |
FDA700-090 Generator display, Frog-D, 3 phase, Delta, 60Hz 90kW |
rtf | |
FDA700-080 Generator display, Frog-D, 3 phase, Delta, 60Hz 80kW |
rtf | |
FDA700-085 Generator display, Frog-D, 3 phase, Delta, 60Hz 85kW |
rtf | |
FDA700-095 Generator display, Frog-D, 3 phase, Delta, 60Hz 95kW |
rtf | |
FDA700-100 Generator display, Frog-D, 3 phase, Delta, 60Hz 100kW |
rtf | |
FDA700-075 Generator display, Frog-D, 3 phase, Delta, 60Hz 75kW |
rtf | |
FDA700-070 Generator display, Frog-D, 3 phase, Delta, 60Hz 70kW |
rtf | |
FDA700-065 Generator display, Frog-D, 3 phase, Delta, 60Hz 65kW |
rtf | |
FDA700-060 Generator display, Frog-D, 3 phase, Delta, 60Hz 60kW |
rtf | |
FDA700-055 Generator display, Frog-D, 3 phase, Delta, 60Hz 55kW |
rtf | |
FDA700-050 Generator display, Frog-D, 3 phase, Delta, 60Hz 50kW |
rtf | |
FDA700-045 Generator display, Frog-D, 3 phase, Delta, 60Hz 45kW |
rtf | |
FDA700-040 Generator display, Frog-D, 3 phase, Delta, 60Hz 40kW |
rtf | |
FDA700-035 Generator display, Frog-D, 3 phase, Delta, 60Hz 35kW |
rtf | |
FDA700-030 Generator display, Frog-D, 3 phase, Delta, 60Hz 30kW |
rtf | |
FDA700-010 Generator display, Frog-D, 3 phase, Delta, 60Hz 10kW |
rtf | |
FDA700-025 Generator display, Frog-D, 3 phase, Delta, 60Hz 25kW |
rtf | |
FDA700-020 Generator display, Frog-D, 3 phase, Delta, 60Hz 20kW |
rtf | |
FDA700-015 Generator display, Frog-D, 3 phase, Delta, 60Hz 15kW |
rtf |